Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 69
Filtrar
1.
Front Med (Lausanne) ; 11: 1384533, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38572159

RESUMO

Background: A positive PET scan at diagnosis was associated with a greater yearly increase in ascending and descending aortic diameter and thoracic aortic volume in patients with giant cell arteritis (GCA). Radiologic and histopathologic vascular abnormalities persist in a subset of treated patients despite clinical remission. The aim of this study was to evaluate the association between vascular FDG uptake during follow-up and the development of thoracic aortic aneurysms. Methods: We recently performed a prospective cohort study of 106 GCA patients, who underwent FDG PET and CT imaging at diagnosis and CT imaging yearly for a maximum of 10 years. In this post hoc analysis, GCA patients who also have had FDG PET imaging during follow-up were included. PET scans were visually scored (0-3) at 7 vascular areas. PET scans were considered positive in case of FDG uptake ≥grade 2 in any large vessel. Results: Eighty-eight repeat PET scans were performed in 52 out of 106 GCA patients, who were included in the original prospective cohort. Fifty-five (63%) PET scans were done at the time of a relapse and 33 (38%) were done while in remission. Nine out of ten patients with an incident thoracic aortic aneurysm had both a positive PET scan at diagnosis and during follow-up. Conclusion: In addition to the intensity and extent of the initial vascular inflammation, ongoing aortic inflammation may contribute to the development of thoracic aortic aneurysms in GCA. However, this hypothesis should be confirmed in a large prospective trial with repeat PET scans at predefined time points during follow-up.

2.
Bone ; 181: 117027, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38309413

RESUMO

Visualization and quantification of bone microarchitecture in the human knee allows gaining insight into normal bone structure, and into the structural changes occurring in the onset and progression of bone diseases such as osteoporosis and osteoarthritis. However, current imaging modalities have limitations in capturing the intricacies of bone microarchitecture. Photon counting computed tomography (PCCT) is a promising imaging modality that presents high-resolution three-dimensional visualization of bone with a large field of view. However, the potential of PCCT in assessing trabecular microstructure has not been investigated yet. Therefore, this study aimed to evaluate the accuracy of PCCT in quantifying bone microstructure and bone mechanics in the knee. Five human cadaveric knees were scanned ex vivo using a PCCT scanner (Naetom alpha, Siemens, Germany) with an in-plane resolution of 146.5 µm and slice thickness of 100 µm. To assess accuracy, the specimens were also scanned with a high-resolution peripheral quantitative computed tomography (HR-pQCT; XtremeCT II, Scanco Medical, Switzerland) with a nominal isotropic voxel size of 60.7 µm as well as with micro-computed tomography (micro-CT; TESCAN UniTOM XL, Czech Republic) with a nominal isotropic voxel size of 25 µm which can be considered gold standards for in vivo and ex vivo scanning, respectively. The thickness and porosity of the subchondral bone and the microstructure of the underlying trabecular bone were assessed in the load bearing regions of the proximal tibia and distal femur. The apparent Young's modulus was determined by micro-finite element (µFE) analysis of subchondral trabecular bone (STB) in the load bearing regions of the proximal tibia using PCCT, HR-pQCT and micro-CT images. The correlation between PCCT measurements and micro-CT and HR-pQCT, respectively, was calculated. The coefficients of determination (R2) between PCCT and micro-CT based parameters, ranged from 0.69 to 0.87. The coefficients of determination between PCCT and HR-pQCT were slightly higher and ranged from 0.71 to 0.91. Apparent Young's modulus, assessed by µFE analysis of PCCT images, correlated well with that of micro-CT (R2 = 0.80, mean relative difference = 19 %). However, PCCT overestimated the apparent Young's modulus by 47 %, but the correlation (R2 = 0.84) remained strong when compared to HR-pQCT. The results of this study suggest that PCCT can be used to quantify bone microstructure in the knee.


Assuntos
Osso e Ossos , Osteoporose , Humanos , Microtomografia por Raio-X/métodos , Osso e Ossos/diagnóstico por imagem , Tíbia/diagnóstico por imagem , Articulação do Joelho/diagnóstico por imagem , Densidade Óssea
3.
Quant Imaging Med Surg ; 14(2): 1729-1746, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38415159

RESUMO

Background: Vascular disrupting agents (VDAs) are known to specifically target preexisting tumoural vasculature. However, systemic side effects as safety or toxicity issues have been reported from clinical trials, which call for further preclinical investigations. The purpose is to gain insights into their non-specific off-targeting effects on normal vasculature and provide clues for exploring underlying molecular mechanisms. Methods: Based on a recently introduced platform consisting laser speckle contrast imaging (LSCI), chick embryo chorioallantoic membrane (CAM), and assisted deep learning techniques, for evaluation of vasoactive medicines, hemodynamics on embryonic day 12 under constant intravascular infusion of two VDAs were qualitatively observed and quantitatively measured in real time for 30 min. Blood perfusion, vessel diameter, vessel density, and vessel total length were further analyzed and compared between blank control and medicines dose groups by using multi-factor analysis of variance (ANOVA) analysis with factorial interactions. Conventional histopathology and fluorescent immunohistochemistry (FIHC) assays for endothelial cytoskeleton including ß-tubulin and F-actin were qualitatively demonstrated, quantitatively analyzed and further correlated with hemodynamic and vascular parameters. Results: The normal vasculature was systemically negatively affected by VDAs with statistical significance (P<0.0001), as evidenced by four positively correlated parameters, which can explain the side-effects observed among clinical patients. Such effects appeared to be dose dependent (P<0.0001). FIHC assays qualitatively and quantitatively verified the results and exposed molecular mechanisms. Conclusions: LSCI-CAM platform combining with deep learning technique proves useful in preclinical evaluations of vasoactive medications. Such new evidences provide new reference to clinical practice.

4.
Eur Radiol ; 34(3): 1895-1904, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37650968

RESUMO

OBJECTIVES: To compare clinical image quality and perceived impact on diagnostic interpretation of chest CT findings between ultra-high-resolution photon-counting CT (UHR-PCCT) and conventional high-resolution energy-integrating-detector CT (HR-EIDCT) using visual grading analysis (VGA) scores. MATERIALS AND METHODS: Fifty patients who underwent a UHR-PCCT (matrix 512 × 512, 768 × 768, or 1024 × 1024; FOV average 275 × 376 mm, 120 × 0.2 mm; focal spot size 0.6 × 0.7 mm) between November 2021 and February 2022 and with a previous HR-EIDCT within the last 14 months were included. Four readers evaluated central and peripheral airways, lung vasculature, nodules, ground glass opacities, inter- and intralobular lines, emphysema, fissures, bullae/cysts, and air trapping on PCCT (0.4 mm) and conventional EIDCT (1 mm) via side-by-side reference scoring using a 5-point diagnostic quality score. The median VGA scores were compared and tested using one-sample Wilcoxon signed rank tests with hypothesized median values of 0 (same visibility) and 2 (better visibility on PCCT with impact on diagnostic interpretation) at a 2.5% significance level. RESULTS: Almost all lung structures had significantly better visibility on PCCT compared to EIDCT (p < 0.025; exception for ground glass nodules (N = 2/50 patients, p = 0.157)), with the highest scores seen for peripheral airways, micronodules, inter- and intralobular lines, and centrilobular emphysema (mean VGA > 1). Although better visibility, a perceived difference in diagnostic interpretation could not be demonstrated, since the median VGA was significantly different from 2. CONCLUSION: UHR-PCCT showed superior visibility compared to HR-EIDCT for central and peripheral airways, lung vasculature, fissures, ground glass opacities, macro- and micronodules, inter- and intralobular lines, paraseptal and centrilobular emphysema, bullae/cysts, and air trapping. CLINICAL RELEVANCE STATEMENT: UHR-PCCT has emerged as a promising technique for thoracic imaging, offering improved spatial resolution and lower radiation dose. Implementing PCCT into daily practice may allow better visibility of multiple lung structures and optimization of scan protocols for specific pathology. KEY POINTS: • The aim of this study was to verify if the higher spatial resolution of UHR-PCCT would improve the visibility and detection of certain lung structures and abnormalities. • UHR-PCCT was judged to have superior clinical image quality compared to conventional HR-EIDCT in the evaluation of the lungs. UHR-PCCT showed better visibility for almost all tested lung structures (except for ground glass nodules). • Despite superior image quality, the readers perceived no significant impact on the diagnostic interpretation of the studied lung structures and abnormalities.


Assuntos
Cistos , Pneumopatias , Enfisema Pulmonar , Humanos , Enfisema Pulmonar/diagnóstico por imagem , Vesícula , Imagens de Fantasmas , Pulmão/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Fótons
5.
Technol Cancer Res Treat ; 22: 15330338231206985, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37844882

RESUMO

Conforming to the current replace-reduce-refine 3Rs' guidelines in animal experiments, a series of explorative efforts have been made to set up operable biomedical imaging-guided platforms for qualitative and quantitative evaluations on pharmacological effects of tumor vascular-disrupting agents (VDAs), based on the chick embryos (CEs) with its chorioallantoic membrane (CAM), in this overview. The techniques and platforms have been hierarchically elaborated, from macroscopic to microscopic and from overall to specific aspects. A protocol of LED lamplight associated with a new deep-learning algorithm was consolidated to screen out weak CEs by using the CAM vasculature imaging. 3D magnetic resonance imaging (MRI) and laser speckle contrast imaging (LSCI) to monitor the evolution of CE and vascular changes in CAM are introduced. A LSCI-CAM platform for studying the effects of VDAs on normal and cancerous vasculature of CAM and possible molecular mechanisms has been demonstrated. Finally, practical challenges and future perspectives are highlighted. The aim of this article is to help peers in biomedical research to familiarize with the CAM platform and to optimize imaging protocols for the evaluation of vasoactive pharmaceuticals, especially anticancer vascular targeted therapy.


Assuntos
Membrana Corioalantoide , Imageamento por Ressonância Magnética , Animais , Embrião de Galinha , Membrana Corioalantoide/irrigação sanguínea , Preparações Farmacêuticas
6.
Ann Intern Med ; 176(10): 1321-1329, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37782924

RESUMO

BACKGROUND: Previous studies have shown that patients with giant cell arteritis (GCA) who have vascular 18F-fluorodeoxyglucose (FDG) uptake at diagnosis are at increased risk for thoracic aortic complications. OBJECTIVE: To measure the association between vascular FDG uptake at diagnosis and the change in aortic dimensions. DESIGN: Prospective cohort study. SETTING: University Hospitals Leuven. PATIENTS: 106 patients with GCA and FDG positron emission tomography (PET) imaging 3 days or less after initiation of glucocorticoids. MEASUREMENTS: Patients had PET and computed tomography (CT) imaging at diagnosis and CT imaging yearly for a maximum of 10 years. The PET scans were scored 0 to 3 in 7 vascular areas and summed to a total vascular score (TVS). The PET scan results were positive when FDG uptake was grade 2 or greater in any large vessel. The association between vascular FDG uptake and aortic dimensions was estimated by linear mixed-effects models with random intercept and slope. RESULTS: When compared with patients with a negative PET scan result, those with a positive scan result had a greater increase in the diameter of the ascending aorta (difference in 5-year progression, 1.58 mm [95% CI, 0.41 to 2.74 mm]), the diameter of the descending aorta (1.32 mm [CI, 0.38 to 2.26 mm]), and the volume of the thoracic aorta (20.5 cm³ [CI, 4.5 to 36.5 cm³]). These thoracic aortic dimensions were also positively associated with TVS. Patients with a positive PET scan result had a higher risk for thoracic aortic aneurysms (adjusted hazard ratio, 10.21 [CI, 1.25 to 83.3]). LIMITATION: The lengthy inclusion and follow-up period resulted in missing data and the use of different PET machines. CONCLUSION: Higher TVS was associated with greater yearly increase in thoracic aortic dimensions. Performing PET imaging at diagnosis may help to estimate the risk for aortic aneurysm formation. PRIMARY FUNDING SOURCE: None.


Assuntos
Fluordesoxiglucose F18 , Arterite de Células Gigantes , Humanos , Arterite de Células Gigantes/complicações , Arterite de Células Gigantes/diagnóstico por imagem , Estudos de Coortes , Estudos Prospectivos , Tomografia por Emissão de Pósitrons/métodos
7.
Am J Physiol Lung Cell Mol Physiol ; 325(5): L675-L688, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37724349

RESUMO

Lung transplantation (LTx) is a challenging procedure. Following the process of ischemia-reperfusion injury, the transplanted pulmonary graft might become severely damaged, resulting in primary graft dysfunction. In addition, during the intraoperative window, the right ventricle (RV) is at risk of acute failure. The interaction of right ventricular function with lung injury is, however, poorly understood. We aimed to address this interaction in a translational porcine model of pulmonary ischemia-reperfusion injury. Advanced pulmonary and hemodynamic assessment was used, including right ventricular pressure-volume loop analysis. The acute model was based on clamping and unclamping of the left lung hilus, respecting the different hemodynamic phases of a clinical lung transplantation. We found that forcing entire right ventricular cardiac output through a lung suffering from ischemia-reperfusion injury increased afterload (pulmonary vascular resistance from baseline to end experiment P < 0.0001) and induced right ventricular failure (RVF) in 5/9 animals. Notably, we identified different compensation patterns in failing versus nonfailing ventricles (arterial elastance P = 0.0008; stroke volume P < 0.0001). Furthermore, increased vascular pressure and flow produced by the right ventricle resulted in higher pulmonary injury, as measured by ex vivo CT density (correlation: pressure r = 0.8; flow r = 0.85). Finally, RV ischemia as measured by troponin-T was negatively correlated with pulmonary injury (r = -0.76); however, troponin-T values did not determine RVF in all animals. In conclusion, we demonstrate a delicate balance between development of pulmonary ischemia-reperfusion injury and right ventricular function during lung transplantation. Furthermore, we provide a physiological basis for potential benefit of extracorporeal life support technology.NEW & NOTEWORTHY In contrast to the abundant literature of mechanical pulmonary artery clamping to increase right ventricular afterload, we developed a model adding a biological factor of pulmonary ischemia-reperfusion injury. We did not only focus on the right ventricular behavior, but also on the interaction with the injured lung. We are the first to describe this interaction while addressing the hemodynamic intraoperative phases of clinical lung transplantation.


Assuntos
Insuficiência Cardíaca , Lesão Pulmonar , Transplante de Pulmão , Traumatismo por Reperfusão , Disfunção Ventricular Direita , Suínos , Animais , Função Ventricular Direita , Troponina T , Pulmão , Hemodinâmica/fisiologia
8.
JVS Vasc Sci ; 4: 100113, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37408594

RESUMO

Objective: Our study was a prospective in vivo study performed on an animal model to evaluate the safety and performance of a novel venous stent designed specifically for venous applications. Methods: The novel stents were implanted in the inferior vena cava of nine sheep. The stents were deployed with different distances between the closed cell rings to test for if the segments might migrate after being deployed at maximal distance. Three different total lengths were 9, 11, and 13 cm. After 1, 3, and 6 months, vascular injury, thrombus, neointima coverage, and stent migration were evaluated through computed tomography venography and histopathology. Imaging, histology, and integration data were analyzed for each group. Results: All stents were deployed successfully, and all sheep survived until the time of harvesting. In all cases, the native blood vessel sections were intact. The segmented stent parts showed a differently pronounced tissue coverage, depending on the duration of the implantation. Conclusions: The new nitinol stent is safe and feasible to implant in the venous system with a rapid surface coverage. Alteration of stent length did not affect the development of neointimal formation and did not cause migration.

9.
Poult Sci ; 102(9): 102902, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37429051

RESUMO

Driven by a global trend of applying replace-reduce-refine or 3Rs' guidance for experimental animals in life sciences, chick embryo and particularly allantois with its chorioallantoic membrane have been increasingly utilized to substitute laboratory animals, which call for more extensive and updated knowledge about this novel experimental setup. In this study, being noninvasive, nonionizing, and super-contrasting with high spatiotemporal resolutions, magnetic resonance imaging (MRI) was chosen as an imaging modality for in ovo monitoring morphologic evolution of the chick embryo, allantois, and chorioallantoic membrane longitudinally throughout embryonic day (ED) 1 until ED20. Cooled in 0°C ice bath for 60 min to reduce MRI motion artifacts, 3 chick embryos (n = 60 in total) on each ED were scanned by a clinical 3.0T MRI scanner to demonstrate 3D images of both T2- and T1-weighted imaging (T2WI, T1WI) sequences at axial, sagittal, and coronal slices. The volumes of both the entire chick embryo and allantois were semi-automatically segmented based on intensity-based thresholding and region-growing algorithms. The morphometries or quantified 3D structures were achieved by refined segmentation, and confirmed by histological analyses (one for each ED). After MRI, the rest of chick embryos (n = 40) continued for incubation. The images from ED2 to ED4 could demonstrate the structural changes of latebra, suggesting its transition into a nutrient supplying channel of yolk sac. The allantois could be recognized by MRI, and its relative volumes on each ED revealed an evolving profile peaked on ED12, with a statistically significant difference from those of earlier and later EDs (P < 0.01). The hypointensity of the yolk due to the susceptibility effect of its enriched iron content overshadowed the otherwise hyperintensity of its lipid components. The chick embryos survived prior cooling and MRI till hatching on ED21. The results could be further developed into a 3D MRI atlas of chick embryo. Clinical 3.0T MRI proved effective as a noninvasive approach to study in ovo 3D embryonic development across the full period (ED1-ED20), which can complement the present knowhow for poultry industry and biomedical science.


Assuntos
Alantoide , Galinhas , Embrião de Galinha , Animais , Imageamento por Ressonância Magnética/veterinária , Imageamento por Ressonância Magnética/métodos , Membrana Corioalantoide , Ferro
10.
United European Gastroenterol J ; 11(7): 633-641, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37278135

RESUMO

BACKGROUND AND AIMS: Polycystic liver disease (PLD) can lead to extensive hepatomegaly. Symptom relief is the primary goal of the treatment. The role of the recently developed disease-specific questionnaires for identification of the thresholds and the assessment of therapy needs further investigation. METHODS: A five-year prospective multi-centric observational study in 21 hospitals in Belgium gathered a study population of 198 symptomatic PLD-patients of whom the disease-specific symptom questionnaire PLD-complaint-specific assessment (POLCA) scores were calculated. The thresholds of the POLCA score for the need for volume reduction therapy were analyzed. RESULTS: The study group consisted of mostly (82.8%) women with baseline mean age of 54.4 years ±11.2, median liver volume expressed as height-adjusted total liver volume(htLV) of 1994 mL (interquartile range [IQR] 1275; 3150) and median growth of the liver of +74 mL/year (IQR +3; +230). Volume reduction therapy was needed in 71 patients (35.9%). A POLCA severity score (SPI) ≥ 14 predicted the need for therapy both in the derivation (n = 63) and the validation cohort (n = 126). The thresholds to start somatostatin analogues (n = 55) or to consider liver transplantation (n = 18) were SPI scores of ≥14 and ≥ 18 and the corresponding mean htLVs were 2902 mL (IQR 1908; 3964) and 3607 mL (IQR 2901; 4337), respectively. Somatostatin analogues treatment resulted in a decrease in the SPI score -6.0 versus + 4.5 in patients without somatostatin analogues (p < 0.01). Changes in the SPI score were significantly different between the liver transplantation group and no liver transplantation group, +4.3 ± 7.1 versus -1.6 ± 4.9, respectively, (p < 0.01). CONCLUSION: A polycystic liver disease-specific questionnaire can be used as a guide on when to start a volume reduction therapy and to assess the effect of treatment.


Assuntos
Hepatopatias , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Estudos Prospectivos , Hepatopatias/diagnóstico , Hepatopatias/etiologia , Hepatopatias/terapia , Somatostatina , Inquéritos e Questionários
11.
Sci Rep ; 13(1): 6266, 2023 04 17.
Artigo em Inglês | MEDLINE | ID: mdl-37069172

RESUMO

Photon-counting computed tomography (PCCT) is an innovative technological advancement in relation to x-ray detectors which offers ultra-high-resolution images. The current study aimed to evaluate the visualization ability of PCCT compared to cone-beam computed tomographic (CBCT) devices for challenging endodontic diagnostic tasks. A reference image of an anthropomorphic phantom was acquired using an industrial micro-CT device. Thereafter, the phantom was scanned with three imaging devices, which included PCCT scanner (NAEOTOM Alpha) and two CBCT devices (3D Accuitomo 170 and NewTom VGi evo) having standard and high-resolution acquisition protocols. The diagnostic tasks involved visualizing fine endodontic structures (apical delta, narrow canal, and isthmus) and root cracks. Three experienced examiners assessed the images and were blinded to the PCCT and CBCT devices. Each image was rated according to a three-grade scale (appropriate, acceptable, or inappropriate) for the diagnostic tasks. In relation to fine endodontic structures grouped together, PCCT showed similar diagnostic performance compared to the reference image (p > 0.05). As for the CBCT devices, an excellent performance was only observed with the 3D Accuitomo 170 device at a high-resolution acquisition mode (p > 0.05). The visualization of root cracks was also better with 3D Accuitomo 170 compared to other devices (p < 0.05). Overall, PCCT and 3D Accuitomo 170 at a high-resolution setting showed similar performance for visualizing fine endodontic structures. In addition, the high-resolution CBCT protocol was superior for visualizing root cracks compared to both PCCT and other standard- and high-resolution CBCT protocols.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Tomografia Computadorizada de Feixe Cônico/métodos , Estudos de Viabilidade , Microtomografia por Raio-X , Imagens de Fantasmas
12.
Eur Radiol ; 33(5): 3222-3231, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36640173

RESUMO

OBJECTIVES: Polycystic liver disease (PLD) is characterized by growth of hepatic cysts, causing hepatomegaly. Disease severity is determined using total liver volume (TLV), which can be measured from computed tomography (CT). The gold standard is manual segmentation which is time-consuming and requires expert knowledge of the anatomy. This study aims to validate the commercially available semi-automatic MMWP (Multimodality Workplace) Volume tool for CT scans of PLD patients. METHODS: We included adult patients with one (n = 60) or two (n = 46) abdominal CT scans. Semi-automatic contouring was compared with manual segmentation, using comparison of observed volumes (cross-sectional) and growth (longitudinal), correlation coefficients (CC), and Bland-Altman analyses with bias and precision, defined as the mean difference and SD from this difference. Inter- and intra-reader variability were assessed using coefficients of variation (CV) and we assessed the time to perform both procedures. RESULTS: Median TLV was 5292.2 mL (IQR 3141.4-7862.2 mL) at baseline. Cross-sectional analysis showed high correlation and low bias and precision between both methods (CC 0.998, bias 1.62%, precision 2.75%). Absolute volumes were slightly higher for semi-automatic segmentation (manual 5292.2 (3141.4-7862.2) versus semi-automatic 5432.8 (3071.9-7960.2) mL, difference 2.7%, p < 0.001). Longitudinal analysis demonstrated that semi-automatic segmentation accurately measures liver growth (CC 0.908, bias 0.23%, precision 4.04%). Inter- and intra-reader variability were small (2.19% and 0.66%) and comparable to manual segmentation (1.21% and 0.63%) (p = 0.26 and p = 0.37). Semi-automatic segmentation was faster than manual tracing (19 min versus 50 min, p = 0.009). CONCLUSIONS: Semi-automatic liver segmentation is a fast and accurate method to determine TLV and liver growth in PLD patients. KEY POINTS: • Semi-automatic liver segmentation using the commercially available MMWP volume tool accurately determines total liver volume as well as liver growth over time in polycystic liver disease patients. • This method is considerably faster than manual segmentation through the use of Hounsfield unit settings. • We used a real-life CT set for the validation and showed that the semi-automatic tool measures accurately regardless of contrast used for the CT scan or not, presence of polycystic kidneys, liver volume, and previous invasive treatment for polycystic liver disease.


Assuntos
Hepatopatias , Tomografia Computadorizada por Raios X , Adulto , Humanos , Estudos Transversais , Tomografia Computadorizada por Raios X/métodos , Hepatopatias/diagnóstico por imagem , Reprodutibilidade dos Testes
13.
Microvasc Res ; 142: 104372, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35483521

RESUMO

Among various anti-cancer therapies, tumor vascular disrupting agents (VDAs) play a crucial role, for which their off-targeting effects on normal vessels need also to be investigated. The purpose of this study was to set up an in-ovo platform that combines a laser speckle contrast imaging (LSCI) modality with chick embryo chorioallantoic membrane (CAM) to real-time monitor vascular diameters and perfusion without and with intravascular injection. Two eggshell windows for both observation or measurement and injection were opened. Dynamic blood perfusion images and corresponding statistic graphs were acquired by using a LSCI unit on CAMs from embryo date (ED) 9 to ED15. A dedicated fine needle catheter was made for slow intravascular administration over 30 min with simultaneous LSCI acquisition. To verify the connectivity between CAM vessels and the embryonic circulations in the egg, contrast-enhanced 3D micro computed tomography (µCT), 2D angiography and histology were executed. This platform was successfully established to acquire, quantify and demonstrate vascular and hemodynamic information from the CAM. Chick embryos even with air cell opened remained alive from ED9 to ED15. Through collecting LSCI derived CAM vascular diameter and perfusion parameters, ED12 was determined as the best time window for vasoactive drug studies. A reverse correlation between CAM vessel diameter and blood perfusion rate was found (p < 0.002). Intravascular infusion and simultaneous LSCI acquisition for 30 min in ovo proved feasible. Contrast-enhanced angiography and histomorphology could characterize the connectivity between CAM vasculature and embryonic circulation. This LSCI-CAM platform was proved effective for investigating the in-ovo hemodynamics, which paves the road for further preclinical research on vasoactive medications including VDAs.


Assuntos
Membrana Corioalantoide , Imagem de Contraste de Manchas a Laser , Animais , Embrião de Galinha , Membrana Corioalantoide/irrigação sanguínea , Microtomografia por Raio-X
14.
Proc Natl Acad Sci U S A ; 119(16): e2114935119, 2022 04 19.
Artigo em Inglês | MEDLINE | ID: mdl-35412896

RESUMO

In humans, obstetrical difficulties arise from the large head and broad shoulders of the neonate relative to the maternal birth canal. Various characteristics of human cranial development, such as the relatively small head of neonates compared with adults and the delayed fusion of the metopic suture, have been suggested to reflect developmental adaptations to obstetrical constraints. On the other hand, it remains unknown whether the shoulders of humans also exhibit developmental features reflecting obstetrical adaptation. Here we address this question by tracking the development of shoulder width from fetal to adult stages in humans, chimpanzees, and Japanese macaques. Compared with nonhuman primates, shoulder development in humans follows a different trajectory, exhibiting reduced growth relative to trunk length before birth and enhanced growth after birth. This indicates that the perinatal developmental characteristics of the shoulders likely evolved to ease obstetrical difficulties such as shoulder dystocia in humans.


Assuntos
Distocia do Ombro , Ombro , Animais , Feminino , Desenvolvimento Fetal , Humanos , Macaca fuscata , Pan troglodytes , Parto , Gravidez , Risco , Ombro/embriologia , Ombro/crescimento & desenvolvimento , Distocia do Ombro/epidemiologia
15.
Medicine (Baltimore) ; 101(9): e28950, 2022 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-35244053

RESUMO

ABSTRACT: To characterize computed tomography (CT) findings of coronavirus disease 2019 (COVID-19) pneumonia and their value in outcome prediction.Chest CTs of 182 patients with a confirmed diagnosis of COVID-19 infection by real-time reverse transcription polymerase chain reaction were evaluated for the presence of CT-abnormalities and their frequency. Regarding the patient outcome each patient was categorized in 5 progressive stages and the duration of hospitalization was determined. Regression analysis was performed to find which CT findings are predictive for patient outcome and to assess prognostic factors for the hospitalization duration.Multivariate statistical analysis confirmed a higher age (OR = 1.023, P  =  .025), a higher total visual severity score (OR = 1.038, P  =  .002) and the presence of crazy paving (OR = 2.160, P  =  .034) as predictive parameters for patient outcome. A higher total visual severity score (+0.134 days; P  =  .012) and the presence of pleural effusion (+13.985 days, P  =  0.005) were predictive parameters for a longer hospitalization duration. Moreover, a higher sensitivity of chest CT (false negatives 10.4%; true positives 78.6%) in comparison to real-time reverse transcription polymerase chain reaction was obtained.An increasing percentage of lung opacity as well as the presence of crazy paving and a higher age are associated with a worse patient outcome. The presence of a higher total visual severity score and pleural effusion are significant predictors for a longer hospitalization duration. These results are underscoring the value of chest CT as a diagnostic and prognostic tool in the pandemic outbreak of COVID-19, to facilitate fast detection and to preserve the limited (intensive) care capacity only for the most vulnerable patients.


Assuntos
COVID-19/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Pneumonia/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Derrame Pleural , Estudos Retrospectivos , SARS-CoV-2
16.
Eur Radiol ; 32(7): 4437-4445, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35238969

RESUMO

OBJECTIVES: To determine the accuracy of scoutless, fixed-dose ultra-low-dose (ULD) CT compared to standard-dose (SD) CT for pulmonary nodule detection and semi-automated nodule measurement, across different patient sizes. METHODS: Sixty-three patients underwent ULD and SD CT. Two readers examined all studies visually and with computer-aided detection (CAD). Nodules detected on SD CT were included in the reference standard by consensus and stratified into 4 categories (nodule category, NODCAT) from the Dutch-Belgian Lung Cancer Screening trial (NELSON). Effects of NODCAT and patient size on nodule detection were determined. For each nodule, volume and diameter were compared between both scans. RESULTS: The reference standard comprised 173 nodules. For both readers, detection rates on ULD versus SD CT were not significantly different for NODCAT 3 and 4 nodules > 50 mm3 (reader 1: 93% versus 89% (p = 0.257); reader 2: 96% versus 98% (p = 0.317)). For NODCAT 1 and 2 nodules < 50 mm3, detection rates on ULD versus SD CT dropped significantly (reader 1: 66% versus 80% (p = 0.023); reader 2: 77% versus 87% (p = 0.039)). Body mass index and chest circumference did not influence nodule detectability (p = 0.229 and p = 0.362, respectively). Calculated volumes and diameters were smaller on ULD CT (p < 0.0001), without altering NODCAT (84% agreement). CONCLUSIONS: Scoutless ULD CT reliably detects solid lung nodules with a clinically relevant volume (> 50 mm3) in lung cancer screening, irrespective of patient size. Since detection rates were lower compared to SD CT for nodules < 50 mm3, its use for lung metastasis detection should be considered on a case-by-case basis. KEY POINTS: • Detection rates of pulmonary nodules > 50 mm3are not significantly different between scoutless ULD and SD CT (i.e. volumes clinically relevant in lung cancer screening based on the NELSON trial), but were different for the detection of nodules < 50 mm3(i.e. volumes still potentially relevant in lung metastasis screening). • Calculated nodule volumes were on average 0.03 mL or 9% smaller on ULD CT, which is below the 20-25% interscan variability previously reported with software-based volumetry. • Even though a scoutless, fixed-dose ULD CT protocol was used (CTDIvol0.15 mGy), pulmonary nodule detection was not influenced by patient size.


Assuntos
Neoplasias Pulmonares , Nódulos Pulmonares Múltiplos , Detecção Precoce de Câncer/métodos , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Estudos Prospectivos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos
17.
EJNMMI Phys ; 9(1): 3, 2022 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-35076801

RESUMO

PURPOSE: Selective internal radiation therapy (SIRT) requires a good liver registration of multi-modality images to obtain precise dose prediction and measurement. This study investigated the feasibility of liver registration of CT and MR images, guided by segmentation of the liver and its landmarks. The influence of the resulting lesion registration on dose estimation was evaluated. METHODS: The liver segmentation was done with a convolutional neural network (CNN), and the landmarks were segmented manually. Our image-based registration software and its liver-segmentation-guided extension (CNN-guided) were tuned and evaluated with 49 CT and 26 MR images from 20 SIRT patients. Each liver registration was evaluated by the root mean square distance (RMSD) of mean surface distance between manually delineated liver contours and mass center distance between manually delineated landmarks (lesions, clips, etc.). The root mean square of RMSDs (RRMSD) was used to evaluate all liver registrations. The CNN-guided registration was further extended by incorporating landmark segmentations (CNN&LM-guided) to assess the value of additional landmark guidance. To evaluate the influence of segmentation-guided registration on dose estimation, mean dose and volume percentages receiving at least 70 Gy (V70) estimated on the 99mTc-labeled macro-aggregated albumin (99mTc-MAA) SPECT were computed, either based on lesions from the reference 99mTc-MAA CT (reference lesions) or from the registered floating CT or MR images (registered lesions) using the CNN- or CNN&LM-guided algorithms. RESULTS: The RRMSD decreased for the floating CTs and MRs by 1.0 mm (11%) and 3.4 mm (34%) using CNN guidance for the image-based registration and by 2.1 mm (26%) and 1.4 mm (21%) using landmark guidance for the CNN-guided registration. The quartiles for the relative mean dose difference (the V70 difference) between the reference and registered lesions and their correlations [25th, 75th; r] are as follows: [- 5.5% (- 1.3%), 5.6% (3.4%); 0.97 (0.95)] and [- 12.3% (- 2.1%), 14.8% (2.9%); 0.96 (0.97)] for the CNN&LM- and CNN-guided CT to CT registrations, [- 7.7% (- 6.6%), 7.0% (3.1%); 0.97 (0.90)] and [- 15.1% (- 11.3%), 2.4% (2.5%); 0.91 (0.78)] for the CNN&LM- and CNN-guided MR to CT registrations. CONCLUSION: Guidance by CNN liver segmentations and landmarks markedly improves the performance of the image-based registration. The small mean dose change between the reference and registered lesions demonstrates the feasibility of applying the CNN&LM- or CNN-guided registration to volume-level dose prediction. The CNN&LM- and CNN-guided registrations for CTs can be applied to voxel-level dose prediction according to their small V70 change for most lesions. The CNN-guided MR to CT registration still needs to incorporate landmark guidance for smaller change of voxel-level dose estimation.

18.
J Belg Soc Radiol ; 105(1): 19, 2021 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-33870083

RESUMO

PURPOSE: To assess the safety and efficacy of main splenic artery embolization. To assess the potential difference post-embolization of the residual splenic volume in patients embolized for trauma versus those embolized for (pseudo)aneurysms. MATERIALS AND METHODS: A retrospective analysis was performed on a cohort of 65 patients (36 males) who underwent pre- and post-embolization computed tomography. Patients' demographics, pre- and post-interventional medical and radiological data were gathered. Splenic volume calculations were semi-automatically performed via a workstation. Patients with splenic aneurysms or pseudoaneurysms of the main splenic artery (group 1) were compared to those with splenic rupture (group 2) using Wilcoxon rank tests. RESULTS: The main indications for splenic artery embolization were splenic rupture (n = 22; 34%) and splenic pseudoaneurysm (n = 19; 29%). The technical success rate was n = 63; 97%. The procedure-related complication rate was n = 7; 11%, including abscess formation (n = 5; 8%), re-bleeding (n = 1; 1.5 %) and pseudoaneurysm re-opening (n = 1; 1.5%). The overall 30-day mortality was n = 7; 11%.Median follow-up for groups 1 and 2 was 1163 days (61-3946 days) and 702 days (43-2095 days) respectively. When processable (n = 23), the splenic volume in group 1 (n = 7) was 311 cm3 and 257 cm3 (p = 0.1591) before and after embolization respectively, and in group 2 (n = 16) it was 261 cm3 and 215 cm3 (p = 0.4688), respectively. CONCLUSIONS: Main splenic artery embolization is efficacious, with low procedure-related complication and 30-day mortality rates. No significant differences in residual post-embolization splenic volume were found between patients treated for splenic rupture versus those treated for splenic arterial (pseudo)aneurysm.

19.
Brain Spine ; 1: 100003, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-36247392

RESUMO

Introduction: Programmable shunt valve settings can sometimes be difficult to assess using classic read-out tools, warranting a skull X-ray. Research question: Can we use available head computed tomography (CT) scans to determine the valve settings, in order to obviate the need for additional skull X-rays? Material and methods: The valve setting of two different programmable shunts (Codman Certas Plus® and Sophysa Polaris®) were assessed by two blinded observers in 24 patients using 65 head CT scans (slice thickness ≤2 â€‹mm). Using multi-planar reconstruction (MPR) tools, images were resliced according to the direction of the valve, allowing a direct readout of the valve settings. We validated our CT based method against 32 available skull X-rays. Results: For all CT scans it was possible to assess the valve setting. No interobserver variability was found and there was a 100 â€‹% concordance between the CT based method and skull X-rays. Discussion: CT based assessment of programmable shunt valve settings is feasible and reliable. It may obviate the need for additional skull x-rays when a head CT scan is available. Conclusions: This technique can reduce radiation exposure and can be applied to historical CT imaging with unknown valve settings.

20.
J Gerontol A Biol Sci Med Sci ; 76(3): 406-414, 2021 02 25.
Artigo em Inglês | MEDLINE | ID: mdl-33284965

RESUMO

Old skeletal muscle exhibits decreased anabolic sensitivity, eventually contributing to muscle wasting. Besides anabolism, also muscle inflammation and catabolism are critical players in regulating the old skeletal muscle's sensitivity. Omega-3 fatty acids (ω-3) are an interesting candidate to reverse anabolic insensitivity via anabolic actions. Yet, it remains unknown whether ω-3 also attenuates muscle inflammation and catabolism. The present study investigates the effect of ω-3 supplementation on muscle inflammation and metabolism (anabolism/catabolism) upon resistance exercise (RE). Twenty-three older adults (65-84 years; 8♀) were randomized to receive ω-3 (~3 g/d) or corn oil (placebo [PLAC]) and engaged in a 12-week RE program (3×/wk). Before and after intervention, muscle volume, strength, and systemic inflammation were assessed, and muscle biopsies were analyzed for markers of anabolism, catabolism, and inflammation. Isometric knee-extensor strength increased in ω-3 (+12.2%), but not in PLAC (-1.4%; pinteraction = .015), whereas leg press strength improved in both conditions (+27.1%; ptime < .001). RE, but not ω-3, decreased inflammatory (p65NF-κB) and catabolic (FOXO1, LC3b) markers, and improved muscle quality. Yet, muscle volume remained unaffected by RE and ω-3. Accordingly, muscle anabolism (mTORC1) and plasma C-reactive protein remained unchanged by RE and ω-3, whereas serum IL-6 tended to decrease in ω-3 (pinteraction = .07). These results show that, despite no changes in muscle volume, RE-induced gains in isometric strength can be further enhanced by ω-3. However, ω-3 did not improve RE-induced beneficial catabolic or inflammatory adaptations. Irrespective of muscle volume, gains in strength (primary criterion for sarcopenia) might be explained by changes in muscle quality due to muscle inflammatory or catabolic signaling.


Assuntos
Suplementos Nutricionais , Ácidos Graxos Ômega-3 , Contração Isométrica/fisiologia , Força Muscular/fisiologia , Músculo Esquelético/metabolismo , Treinamento de Força , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Método Duplo-Cego , Feminino , Humanos , Perna (Membro) , Masculino , Transdução de Sinais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...